Assessment of Current ACI 440.2R-08 Design Guidelines and Evaluation of Hoop Strain in FRP Confined Concrete

dc.contributor.advisorTalley, Kimberly G.
dc.contributor.authorUgartechea Garcia, Ana Daniela
dc.contributor.committeeMemberKim, Yoo-Jae
dc.contributor.committeeMemberMuniz Solari, Osvaldo
dc.date.accessioned2017-01-05T18:51:32Z
dc.date.available2017-01-05T18:51:32Z
dc.date.issued2014-08
dc.description.abstractStrengthening concrete structures with fiber reinforced polymers (FRP) is becoming increasingly common in construction practice. The currently available design guideline for FRP confined concrete is the ACI 440.2R-08 model for predicting the maximum confined compressive strength. These formulas are based on a modest test dataset of carbon fiber reinforced polymers (CFRP) and a small test dataset of glass fiber reinforced polymers (GFRP) wrapped specimens. This investigation reviewed a meta- analysis of published testing data from CFRP and GFRP-wrapped plain concrete specimens to evaluate the performance of the design guidelines. The results from 694 compression tests are compared to the predicted maximum confined compressive strength following the ACI 440.2R-08 design formulas. The investigation showed that for CFRP- wrapped plain concrete specimens the design formulas work reasonably well, 82% of the values are conservative. However for the GFRP-wrapped specimens, it was found that one third of the tested specimens had capacities that were less than the design guidelines’ prediction. Therefore the current design formula is unconservative for the design of GFRP-wrapped specimens. In order to suggest a conservative design formula, a variation of the existing formula for calculating the confined compressive strength of a GFRP- wrapped specimen is presented. Also, a variation was made for CFRP-confined concrete specimens to make the formula more conservative. Additionally, an investigation of the transfer of strain between FRP layers in FRP confined concrete specimens was completed. Glass fibers were applied to plain concrete specimens, with the number of layers ranging from one to three layers. Strain gages were placed on every layer to perform an analysis of the hoop strains under load. The results showed that the different layers of a GFRP wrap on a specimen do not receive the same amount of strain for the same axial compressive load on the cylinder. This inequality could be a possible explanation for why FRP jackets do not achieve the same tensile strength as the results from tensile coupon tests.
dc.description.departmentEngineering Technology
dc.formatText
dc.format.extent120 pages
dc.format.medium1 file (.pdf)
dc.identifier.citationUgartechea Garcia, A. D. (2014). <i>Assessment of current ACI 440.2R-08 design guidelines and evaluation of hoop strain in FRP confined concrete</i> (Unpublished thesis). Texas State University, San Marcos, Texas.
dc.identifier.urihttps://hdl.handle.net/10877/6378
dc.language.isoen
dc.subjectFRP
dc.subjectConfined concrete
dc.subjectACI
dc.titleAssessment of Current ACI 440.2R-08 Design Guidelines and Evaluation of Hoop Strain in FRP Confined Concrete
dc.typeThesis
thesis.degree.departmentEngineering Technology
thesis.degree.disciplineIndustrial Technology
thesis.degree.grantorTexas State University
thesis.degree.levelMasters
thesis.degree.nameMaster of Science in Technology

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
UGARTECHEAGARCIA-THESIS-2014.pdf
Size:
21.1 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
LICENSE.txt
Size:
2.14 KB
Format:
Plain Text
Description: