Two-Dimensional Linear Homeomorphic Oculomotor Plant Mathematical Model

dc.contributor.authorKomogortsev, Oleg V.
dc.contributor.authorHolland, Corey D.
dc.contributor.authorJayarathna, Sampath
dc.date.accessioned2012-06-10T22:15:48Z
dc.date.available2012-06-10T22:15:48Z
dc.date.issued2012-06-10
dc.description.abstractThis paper builds a two-dimensional linear homeomorphic oculomotor plant mathematical model and assesses its ability to simulate person-specific oblique saccades on a two-dimensional plane. The proposed model is driven by a simplified pulse-step neuronal control signal and accounts in a linear form for the unique characteristics of the eye globe and the extraocular muscles responsible for horizontal and vertical rotation (the lateral/medial recti and superior/inferior recti respectively). These characteristics include: series elasticity, length tension, passive elasticity, viscosity, eye globe inertial mass, and the force-velocity relationships of agonist/antagonist muscles. Results indicate that the model is capable of producing oblique saccade trajectories with properties resembling those of normal humans. The model can be simplified into two one-dimensional models for quicker signal simulation, making it applicable for time sensitive applications. Practical applications of the model might include: enhanced security in biometric identification systems; improved noise reduction and signal recovery facilities for eye tracking systems; and additional metrics from which to determine user effort during usability testing.
dc.description.departmentComputer Science
dc.description.sponsorshipNational Institute of Standards and Technology (NIST) under Grant #60NANB10D213 National Science Foundation (NSF) under Grant #DGE-11444666
dc.formatText
dc.format.extent12 pages
dc.format.medium1 file (.pdf)
dc.identifier.citationKomogortsev, O. V., Holland, C., & Jayarathna, S. (2012). Two-dimensional linear homeomorphic oculomotor plant mathematical model (Report No. TXSTATE-CS-TR-2012-6). Texas State University-San Marcos, Department of Computer Science.
dc.identifier.urihttps://hdl.handle.net/10877/4156
dc.language.isoen
dc.subjectoculomotor plant
dc.subjectmodel
dc.subjectsimulation
dc.subjectprediction
dc.subjecthuman visual system
dc.subjectsaccade
dc.subjectComputer Science
dc.titleTwo-Dimensional Linear Homeomorphic Oculomotor Plant Mathematical Model
dc.typeTechnical Report

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
TR2012_06_10_2DOP_Ko_Ho_Ja.pdf
Size:
785.59 KB
Format:
Adobe Portable Document Format
Description:
Main article

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.54 KB
Format:
Item-specific license agreed upon to submission
Description: